User Tools

Site Tools


projects:challenger604:drainmast

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
projects:challenger604:drainmast [2019/09/27 03:40]
dwheele [Line Heater]
projects:challenger604:drainmast [2019/09/27 04:22] (current)
dwheele
Line 1: Line 1:
 ====== Heated Drain Mast ====== ====== Heated Drain Mast ======
  
-On the Challenger 604, the forward Drain Mast heater is electrically open. The symptoms reported by the crew are that the circuit breaker keeps popping. Perhaps this is caused by an electrical wire internal to the heater shorting to ground.+On the Challenger 604, the crew reported that the Drain/Line Heater circuit breaker in the Galley keeps popping when in the air. 
 + 
 +We measured the forward Drain Mast heater and discovered that it is electrically open.
  
 ^Heated Drain Mast|115677-114|Electrofilm Mfg. Inc.| ^Heated Drain Mast|115677-114|Electrofilm Mfg. Inc.|
Line 12: Line 14:
   * Sent another RFQ to https://crsjetspares.com/ [7/10/2019 1:45 p.m.]   * Sent another RFQ to https://crsjetspares.com/ [7/10/2019 1:45 p.m.]
   * Sent another https://www.aerospaceunlimited.com/rfq/thankyou?name=Dan%20Wheeler&Cname=604%20Challenger&Ctype=Airlines/Charter%20Operator&email=dan@quizkid.net&phn=206-387-7127&Part=115677-114&need=Immediate%20Buy&Qty=1&IsnewsLetter=False&type=rfq [7/10/2019 5:33 p.m.]   * Sent another https://www.aerospaceunlimited.com/rfq/thankyou?name=Dan%20Wheeler&Cname=604%20Challenger&Ctype=Airlines/Charter%20Operator&email=dan@quizkid.net&phn=206-387-7127&Part=115677-114&need=Immediate%20Buy&Qty=1&IsnewsLetter=False&type=rfq [7/10/2019 5:33 p.m.]
 +
 +Note that while this schematic page is excellent, what is absent from the drawing is that Pin B1 on the relay is actually connected to Pin c (lower case, with bar), which connects to "L" in a hex shape and then to multiple line heaters via two terminal blocks.
  
 {{:projects:challenger604:fr_395.jpg?direct&600|}} {{:projects:challenger604:fr_395.jpg?direct&600|}}
Line 17: Line 21:
 ===== Circuit Breaker ===== ===== Circuit Breaker =====
  
-The relevant circuit breaker (probably not defective): 7274-11-7 1/2 Klixon, 7.5 amp. The schematic specifies that the expected draw is .96 amps. There are two Drain Masts. The forward was open, and the rearward was about 64 ohms (about 100 ohms expected).+The relevant circuit breaker (probably not defective): 7274-11-7 1/2 Klixon, 7.5 amp. The schematic specifies that the expected draw is .96 amps. There are two Drain Masts. The forward was open, and the rearward was about 64 ohms (about 100 ohms expected). This circuit breaker supplies 115V at 400 Hz. 
 + 
 +**Galley Circuit Breakers** 
 + 
 +There is a panel of circuit breakers located to the forward part of the upper galley. The relevant circuit breaker for the Drain/Line Heater is mounted to the front in the same way as the others, and the output wire travels to the back via J22 (J25 is visible). Tracing the route of this wire was difficult. Found that it went to the relay panel located behind the Ice Box. 
 + 
 +{{:projects:challenger604:galleycircuitbreakers.jpg?direct&400|Galley Circuit Breakers}}
  
 ===== Solution ===== ===== Solution =====
  
-Discovered that there was a line heater for the Water Valve, located in the cargo hold area, that was shorted against a bolt. Severe charring was present.+After multiple troubleshooting steps, discovered that there was a line heater for the Water Valve (FILL SOLENOID, see schematic below), located in the cargo hold area, right side, that was shorted against a bolt. Severe charring was present. 
 + 
 +For the aircraft to be flyable, awaiting the acquisition of a replacement line heater, we disconnected the lead going to the line heater, and also clipped that wire near the point it connected to the heater, and removed the line heater. Tied back the lead with crimped-loop and zip-tied to wire bundle for safety. 
 + 
 +^Testing|Tested by powering the aircraft, and resetting 7.5 circuit breaker. Jumpered Thermal Switch sensor to ground to activate relay (required because temperature was not below 40 degrees, and the aircraft is not in the air).|
  
-For the aircraft to be flyablewe disconnected the lead going to the line heaterand also clipped that wire near the point it connected to the heater, and removed the heater. Tied back the lead with crimped-loop and zip tied to wire bundle.+^Result|System seems stableaft drain mast is obviously heatedmeasured by feeling it from outside.|
  
-Powered the aircraftresetting 7.5 circuit breaker. System seems stable, aft drain mast is obviously heatedmeasured by feeling it from outside.+^Remaining Steps|We will need to acquire a replacement Forward Drain Mastand Fill Solenoid Ribbon Heaterand install them.|
  
 ===== Steps to the Solution, Narrative ===== ===== Steps to the Solution, Narrative =====
Line 39: Line 53:
  
 Powered system. Disconnected connector Thermal Switch connector J31. Jumpered across the two pins.  Powered system. Disconnected connector Thermal Switch connector J31. Jumpered across the two pins. 
-Jumpered J31 connector pulls diode cathode to ground. With Forward Drain mast connector disconnected,  +Jumpered J31 connector pulls diode cathode to ground. Even with Forward Drain mast connector disconnected,  
-Drain/Line Heater circuit break pops immediately.+Drain/Line Heater circuit breaker pops immediately.
  
-Disconnected After Drain Mast Heater at J21. Repeated same test as above, with Powered system, and +Disconnected AFT Drain Mast Heater at J21. Repeated same test as above, with Powered system, and 
 Jumpered connector J31, Drain/Line Heater circuit break pops immediately. Jumpered connector J31, Drain/Line Heater circuit break pops immediately.
  
Line 49: Line 63:
 and because J103 (which has about 40 pins) is shown as connected to K16, and also to the Cabin Control Accessory Unit. and because J103 (which has about 40 pins) is shown as connected to K16, and also to the Cabin Control Accessory Unit.
  
-Circuit breaker only pops when relay K16 is activated.+Circuit breaker only pops when relay K16 is activated, an important fact.
  
-Suspect J103 has damage around pins a, b, or c. Or Relay K16 has unused pin B1 grounded or is otherwise damaged.+[9/25/2019 conclusion] Suspect J103 has damage around pins a, b, or c. Or Relay K16 has unused pin B1 grounded or is otherwise damaged. //Turned out this conclusion was close. Pin B1 was grounded, but via additional Line Heater wiring. See schematic below.//
  
 David came today to help with the Challenger 604. David came today to help with the Challenger 604.
 +
 +==== Captain's Circuit Break Blown ====
 +
 +The Pilots discovered that the circuit breaker **Galley Supply 1** was thrown. Photo shows the breaker in the thrown position, although it is hard to see. After some thought, it was concluded that this was caused by some troubleshooting on a previous session. This breaker apparently is upstream of the Galley Heaters, including the Drain Mast and Line Heaters. 
 +
 +{{:projects:challenger604:captaincircuitbreakers.jpg?direct&400|}}
 +
  
 ==== Found Relay K16 ==== ==== Found Relay K16 ====
  
-We looked at additional locations, including in the tunnel, and in the closet. While my brother +[9/25/2019] We looked at additional locations, including in the tunnel, and in the closet. (We looked in the closet because there was another J103 connector in the tunnel, with wiring traced to the cabin closet. This wiring was evidently part of the emergency lighting system.) While my brother 
-was looking in the closet, I was bored and looked in some of the drawers. Noticed when looking +was continuing our search by looking in the closet, I rechecked some of the galley drawer backs. Noticed when looking behind the ice boxthere is a panel with screws in the corners. We removed this, and the  
-in the ice box that there was a panel with screws in the corners. We removed this, and the  +relay panel was inside. Although we had examined nearly every other drawer in the lower galley area (below the counter), we hadn't noticed this before this day. No documentation available to us explained the location of the important panel. The only explanation was "Lower Galley."
-relay panel was inside.+
  
 **Relay Panel Location** **Relay Panel Location**
Line 75: Line 95:
  
 {{:projects:challenger604:relayk16closeup.jpg?direct&400|}} {{:projects:challenger604:relayk16closeup.jpg?direct&400|}}
- 
  
  
Line 83: Line 102:
 {{:projects:challenger604:canonplusbackofrelayk16panel.jpg?direct&400|Canon Plug at rear of relay panel}} {{:projects:challenger604:canonplusbackofrelayk16panel.jpg?direct&400|Canon Plug at rear of relay panel}}
  
-But when we looked at the schematics, discovered that this +[9/26/2019] But when we looked at the schematics, discovered that this 
-is connected to a line heater. The schematic for the Drain Mast doesn't show anything connected to pin c, or relay B1. +is connected to a line heater. The schematic for the Drain Mast (above) doesn't show anything connected to pin c, or relay B1. 
  
 This probably accounts for the circuit breaker blowing. This probably accounts for the circuit breaker blowing.
Line 90: Line 109:
 --------------------------- ---------------------------
  
-**Schematic** showing wiring for Line Heaters. The heater which was shorted to the bolt is called "FILL SOLENOID" wire 1WTR017H18. The terminal block called "1WTR TB2 LAV VANITY" is actually located in the panel at right of Cargo Hold. Wire with a "L" in hex shape goes to the K16 Relay, Pin B1, via wire ''c''+**Schematic** showing wiring for Line Heaters. The heater which was shorted to the bolt is called "FILL SOLENOID" wire 1WTR017H18. The terminal block called "1WTR TB2 LAV VANITY" is actually located in the panel at right of Cargo Hold. Wire with a "L" in hex shape goes to the K16 Relay, Pin B1, via wire ''c''. Because this was the solution, we did not need to find TB1 (Terminal Block 1). A wild guess is that it is located somewhere behind/below the galley sink.
  
 {{:projects:challenger604:midcoastwatersystemschematic_r.jpg?direct&400|}} {{:projects:challenger604:midcoastwatersystemschematic_r.jpg?direct&400|}}
Line 103: Line 122:
    207 watts    207 watts
        
-Pin C (originally thought was one line heater, but schematic shows various line heaters)+Pin C (originally thought was just one line heater, but schematic shows various line heaters). These values indicate the short, the subject of this narrative.
    16 ohms    16 ohms
    7.2 amps    7.2 amps
Line 119: Line 138:
 ==== Ribbon Heater ==== ==== Ribbon Heater ====
  
-{{:projects:challenger604:ribbonheaterlabelreverse.jpg?direct&400|}}+{{:projects:challenger604:ribbonheaterlabelreverse.jpg?direct&300|}}
  
-{{:projects:challenger604:ribbonheaterlabel.jpg?direct&600|}}+{{:projects:challenger604:ribbonheaterlabel.jpg?direct&300|}}
  
 According to other references, the unreadable part number was probably 3043-110-6-621. According to other references, the unreadable part number was probably 3043-110-6-621.
projects/challenger604/drainmast.1569555633.txt.gz · Last modified: 2019/09/27 03:40 by dwheele