projects:challenger604:doorhandlelatchswitch [2022/10/15 03:56] dwheele [Door Handle Stow Failure not Indicating on EICAS] |
projects:challenger604:doorhandlelatchswitch [2022/10/15 04:07] (current) dwheele |
||
|---|---|---|---|
| Line 7: | Line 7: | ||
| This shows the location of the main Canon plug (under floor steel panel), and some photos taken at the top of the door (when closed) | This shows the location of the main Canon plug (under floor steel panel), and some photos taken at the top of the door (when closed) | ||
| - | {{: | + | These proximity switches detect that the latches are closed. The latches rotate into position a large metal " |
| + | {{: | ||
| + | |||
| + | Proximity switches at top of the door. | ||
| + | |||
| + | ------------------------------------- | ||
| + | |||
| + | {{: | ||
| + | |||
| + | {{: | ||
| ===== Notes ===== | ===== Notes ===== | ||
| Line 18: | Line 27: | ||
| {{: | {{: | ||
| + | |||
| + | ===== Door Warn 3-Amp Breaker ===== | ||
| + | |||
| + | Did some simple tests and determined that the Door Warn 3-Amp Breaker (behind first officer) is working, however did not see any effect when turned on or off. According to the schematic, this only powers the Inner Latch proximity switches, and since we had the door open, this may have inhibited the warning. | ||