projects:a4work:consolelights [2019/01/09 04:29]
dwheele [Work Notes]
projects:a4work:consolelights [2019/01/09 04:29] (current)
dwheele [Solution]
Line 34: Line 34:
 ===== Solution ===== ===== Solution =====
  
-Created a new terminal tip conductor. Purchased a white nylon bushing of the proper size at Ace Hardware for $.37. Sanded it to fit. Soldered new tip conductor to wire, a two-man job to prevent dropping anything. Added heat shrinkable tubing to prevent shorts.+Created a new terminal tip conductor from small copper pipe. Purchased a white nylon bushing of the proper size at Ace Hardware for $.37. Sanded it, reducing its diameter to fit. Soldered new tip conductor to wire in canopy, a two-man job to prevent dropping anything. Added heat shrinkable tubing to prevent shorts.
  
 1/8/2019. 1/8/2019.
  
  
projects/a4work/consolelights.1547008143.txt.gz ยท Last modified: 2019/01/09 04:29 by dwheele